62.5 µm Multimode Cable, Tight Buffered Riser, and Plenum for Lashed Aerial, Duct, Underground Conduit and Indoor Plenum Applications
Hitachi Bulk Cable, 62.5/125 µm Multimode, 62.5/125 µm StratusClear" Multimode
62.5/125 µm Multimode Tight Buffered Cable - Riser - Plenum
Bulk Indoor/Outdoor Fiber Optic Cable
- UV Resistant Jacket
- Tight Buffered Construction
- Each Fiber is Color Coded for Easy Identification
- Dry, Super Absorbent Polymers (SAPs) Eliminate Water Migration in Cable Interstices
- Suitable for Lashed Aerial, Duct, Underground Conduit and Indoor Riser Applications
62.5/125 µm Multimode Tight Buffered Riser Cable - (UL) OFNR c(UL)us FT4
Part No.
|
Fibers
per
Tube
|
Fiber Count
|
Tube Layout
|
Cable OD
in (mm)
|
Maximum Load Install
lbs-f (N)
|
Operation
lbs-f (N)
|
Weight
lbs/1000ft (kg/1000m)
|
OM1 - 62.5/125 µm Multimode Cable (62.5/125/250/900)
|
61345-2
|
X
|
2
|
X
|
.190 (4.8)
|
128 (570)
|
64 (285)
|
12.6 (18.8)
|
61345-4
|
X
|
4
|
X
|
.190 (4.8)
|
128 (570)
|
64 (285)
|
13.9 (20.7)
|
61345-6
|
X
|
6
|
X
|
.190 (4.8)
|
128 (570)
|
64 (285)
|
15.1 (22.5)
|
61345-8
|
X
|
8
|
X
|
.230 (5.8)
|
160 (712)
|
80 (356)
|
20.0 (29.8)
|
61345-10
|
X
|
10
|
X
|
.230 (5.8)
|
160 (712)
|
80 (356)
|
21.3 (31.7)
|
61345-12
|
X
|
12
|
X
|
.230 (5.8)
|
160 (712)
|
80 (356)
|
22.5 (33.5)
|
61345-24
|
X
|
24
|
X
|
.350 (8.8)
|
288 (1282)
|
144 (641)
|
52.4 (78.1)
|
61380-36
|
6
|
36
|
6xCSM
|
.657 (16.7)
|
600 (2671)
|
200 (890)
|
135.0 (201.2)
|
61495-48
|
12
|
48
|
4xCSM
|
.64 (16.4)
|
600 (2671)
|
200 (890)
|
145.0 (216.1)
|
61495-72
|
12
|
72
|
6xCSM
|
.816 (20.7)
|
600 (2671)
|
200 (890)
|
156.7 (233.5)
|
OM1 - 62.5/125 µm StratusClear Multimode Cable (62.5/125/250/900)
|
61346-2
|
X
|
2
|
X
|
.190 (4.8)
|
128 (570)
|
64 (285)
|
12.6 (18.8)
|
61346-4
|
X
|
4
|
X
|
.190 (4.8)
|
128 (570)
|
64 (285)
|
13.9 (20.7)
|
61346-6
|
X
|
6
|
X
|
.190 (4.8)
|
128 (570)
|
64 (285)
|
15.1 (22.5)
|
61346-8
|
X
|
8
|
X
|
.230 (5.8)
|
160 (712)
|
80 (356)
|
20.0 (29.8)
|
61346-10
|
X
|
10
|
X
|
.230 (5.8)
|
160 (712)
|
80 (356)
|
21.3 (31.7)
|
61346-12
|
X
|
12
|
X
|
.230 (5.8)
|
160 (712)
|
80 (356)
|
22.5 (33.5)
|
61346-24
|
X
|
24
|
X
|
.350 (8.8)
|
288 (1282)
|
144 (641)
|
52.4 (78.1)
|
61525-36
|
6
|
36
|
6xCSM
|
.657 (16.7)
|
600 (2671)
|
200 (890)
|
135.0 (201.2)
|
61526-48
|
12
|
48
|
4xCSM
|
.647 (16.4)
|
600 (2671)
|
200 (890)
|
145.0 (216.1)
|
61526-72
|
12
|
72
|
6xCSM
|
.816 (20.7)
|
600 (2671)
|
200 (890)
|
156.7 (233.5)
|
62.5/125 µm Multimode Tight Buffered Plenum Cable - (UL) OFNP c(UL)us FT6
Part No.
|
Fiber Count
|
Cable OD
in (mm)
|
Maximum Load Install
lbs-f (N)
|
Operation
lbs-f (N)
|
Weight
lbs/1000ft (kg/1000m)
|
OM1 - 62.5/125 µm Multimode Cable (62.5/125/250/900)
|
61460-2
|
2
|
.190 (4.8)
|
128 (570)
|
64 (285)
|
15.3 (22.8)
|
61460-4
|
4
|
.190 (4.8)
|
128 (570)
|
64 (285)
|
16.6 (24.7)
|
61460-6
|
6
|
.190 (4.8)
|
128 (570)
|
64 (285)
|
17.8 (26.5)
|
61460-8
|
8
|
.230 (5.8)
|
160 (712)
|
80 (356)
|
23.5 (35.0)
|
61460-10
|
10
|
.230 (5.8)
|
160 (712)
|
80 (356)
|
24.8 (36.9)
|
61460-12
|
12
|
.230 (5.8)
|
160 (712)
|
80 (356)
|
26.0 (38.7)
|
61460-24
|
24
|
.350 (8.8)
|
288 (1282)
|
144 (641)
|
52.4 (78.1)
|
OM1 - 62.5/125 µm StratusClear Multimode Cable (62.5/125/250/900)
|
61467-2
|
2
|
.190 (4.8)
|
128 (570)
|
64 (285)
|
15.3 (22.8)
|
61467-4
|
4
|
.190 (4.8)
|
128 (570)
|
64 (285)
|
16.6 (24.7)
|
61467-6
|
6
|
.190 (4.8)
|
128 (570)
|
64 (285)
|
17.8 (26.5)
|
61467-8
|
8
|
.230 (5.8)
|
160 (712)
|
80 (356)
|
23.5 (35.0)
|
61467-10
|
10
|
.230 (5.8)
|
160 (712)
|
80 (356)
|
24.8 (36.9)
|
61467-12
|
12
|
.230 (5.8)
|
160 (712)
|
80 (356)
|
26.0 (38.7)
|
61467-24
|
24
|
.350 (8.8)
|
288 (1282)
|
144 (641)
|
52.4 (78.1)
|
Tight Buffered Cable Applications
- Indoor / Outdoor Applications Where Gel-Filled Cables are not Suitable
- Robust Cables for Indoor Applications where the Cable may be Subject to a Damp / Moist Environment
- Indoor / Outdoor Applications where Termination is Directly onto Conventional Connectors (w/o pigtail splicing)
- Suitable for Lashed Aerial, Duct, Underground Conduit and Indoor Riser Applications
Tight Buffered Cable Optical Specifications
TIA/EIA-568-B.3/B.3-1
ISO/IEC 11801, 2nd Edition
Bellcore GR-409-CORE
|
62.5/125 µm Multimode
(OM1)
|
StratusClear 62.5/125 µm Multimode
(OM1)
|
Maximum Attenuation
|
≤3.5 dB/km @ 850 nm
≤1.0 dB/km @ 1300 nm
|
≤3.25 dB/km @ 850 nm
≤1.0 dB/km @ 1300 nm
|
Minimum Bandwidth (OFL)
|
200 MHz/km @ 850 nm
500 MHz/km @ 1300 nm
|
200 MHz/km @ 850 nm
500 MHz/km @ 1300 nm
|
Minimum Bandwidth (RML)
|
220 MHz/km @ 850 nm
n/s
|
385 MHz/km @ 850 nm
n/s
|
Gigabit Ethernet Support Distance
|
300 m @ 850 nm
550 m @ 1300 nm
|
500 m @ 850 nm
1000 m @ 1300 nm
|
Tight Buffered Cable Mechanical Specifications
- Bend Radius, No Load = 10x Cable Overall Diameter
- Bend Radius, Load = 15x Cable Overall Diameteroor Applications where Termination is Direct
|