50multimode-outdoor-loose-tube-cables50/125µm StratusClear Multimode Loose Tube Outdoor Cables

Hitachi Bulk Fiber, 12 through 432 Fiber, 50/125µm Multimode OM2, OM3, 50/125 µm Stratus Clear Multimode, RoHS compliant0/125 µm Multimode Loose Tube Cable

Bulk Outdoor Fiber Optic Cable

  • UV Resistant Jacket
  • Gel Filled Loose Tubes Provide Protection Against Water Penetration
  • Dry, Super Absorbent Polymers (SAPs) Eliminate Water Migration in Cable Interstices
  • Suitable for Lashed Aerial, Duct, Underground Conduit Applications

50/125 µm Multimode Loose Tube Outdoor Cable

Part No.

Fibers
per
Tube

Fiber Count

Tube Layout

Cable OD
in (mm)

Maximum
Load Install
lbs-f (N)

Operation
lbs-f (N)

Weight
lbs/1000ft (kg/1000m)

OM2 - 50/125 µm Multimode Cable (50/125/250)

60282-12

2

12

6xCSM

.493 (12.5)

600 (2670)

200 (890)

74.0 (110.3)

60282-24

2

24

12xCSM

.700 (17.8)

600 (2670)

200 (890)

160.0 (238.4)

60408-24

4

24

6xCSM

.493 (12.5)

600 (2670)

200 (890)

75.0 (111.8)

60408-48

4

48

12xCSM

.700 (17.8)

600 (2670)

200 (890)

160.0 (238.4)

60087-18

6

18

5xCSM

.463 (11.7)

600 (2670)

200 (890)

56.0 (83.4)

60087-24

6

24

5xCSM

.463 (11.7)

600 (2670)

200 (890)

60.0 (89.4)

60087-36

6

36

6xCSM

.493 (12.5)

600 (2670)

200 (890)

75.0 (111.8)

60087-48

6

48

8xCSM

.561 (14.2)

600 (2670)

200 (890)

97.0 (144.5)

60088-12

12

12

5xCSM

.463 (11.7)

600 (2670)

200 (890)

48.0 (71.5)

60088-24

12

24

5xCSM

.463 (11.7)

600 (2670)

200 (890)

52.0 (77.5)

60088-36

12

36

5xCSM

.463 (11.7)

600 (2670)

200 (890)

56.0 (83.4)

60088-48

12

48

5xCSM

.463 (11.7)

600 (2670)

200 (890)

60.0 (89.4)

60088-60

12

60

5xCSM

.463 (11.7)

600 (2670)

200 (890)

64.0 (95.4)

60088-72

12

72

6xCSM

.493 (12.5)

600 (2670)

200 (890)

76.0 (113.2)

60088-84

12

84

7xCSM

.552 (14.0)

600 (2670)

200 (890)

93.0 (138.6)

60088-96

12

96

8xCSM

.581 (14.8)

600 (2670)

200 (890)

106.0 (157.9)

60088-108

12

108

9xCSM

.620 (15.7)

600 (2670)

200 (890)

120.0 (178.8)

60088-120

12

120

10xCSM

.649 (16.5)

600 (2670)

200 (890)

137.0 (204.1)

60088-132

12

132

11xCSM

.683 (17.3)

600 (2670)

200 (890)

153.0 (228.0)

60088-144

12

144

12xCSM

.720 (18.3)

600 (2670)

200 (890)

171.0 (255.0)

60088-168

12

168

12x6xCSM

.737 (18.7)

600 (2670)

200 (890)

143.0 (213.1)

60088-192

12

192

12x6xCSM

.737 (18.7)

600 (2670)

200 (890)

151.0 (225.0)

60088-216

12

216

12x6xCSM

.737 (18.7)

600 (2670)

200 (890)

159.0 (236.9)

60088-240

12

240

13x7xCSM

.770 (19.6)

600 (2670)

200 (890)

175.0 (260.8)

60088-264

12

264

14x8xCSM

.805 (20.4)

600 (2670)

200 (890)

196.0 (292.0)

60088-288

12

288

15x9xCSM

.835 (21.2)

600 (2670)

200 (890)

213.0 (317.4)

60088-312

12

312

16x10xCSM

.870 (22.1)

600 (2670)

200 (890)

233.0 (347.2)

60088-336

12

336

17x11xCSM

.902 (22.9)

600 (2670)

200 (890)

255.0 (380.0)

60088-360

12

360

18x12x6xCSM

.956 (24.3)

600 (2670)

200 (890)

241.0 (359.1)

60088-384

12

384

18x12x6xCSM

.956 (24.3)

600 (2670)

200 (890)

249.0 (371.0)

60088-432

12

432

18x12x6xCSM

.956 (24.3)

600 (2670)

200 (890)

266.0 (396.3)

50/125 µm Multimode StratusClear Loose Tube Outdoor Cable

Part No.

Fibers
per
Tube

Fiber Count

Tube Layout

Cable OD
in (mm)

Maximum
Load Install
lbs-f (N)

Operation
lbs-f (N)

Weight
lbs/1000ft (kg/1000m)

OM3 - 50/125 µm StratusClear Multimode Cable (50/125/250)

60938-12

2

12

6xCSM

.493 (12.5)

600 (2670)

200 (890)

74.0 (110.3)

60938-24

2

24

12xCSM

.700 (17.8)

600 (2670)

200 (890)

160.0 (238.4)

60939-24

4

24

6xCSM

.493 (12.5)

600 (2670)

200 (890)

75.0 (111.8)

60939-48

4

48

12xCSM

.700 (17.8)

600 (2670)

200 (890)

160.0 (238.4)

60940-18

6

18

5xCSM

.463 (11.7)

600 (2670)

200 (890)

56.0 (83.4)

60940-24

6

24

5xCSM

.463 (11.7)

600 (2670)

200 (890)

60.0 (89.4)

60940-36

6

36

6xCSM

.493 (12.5)

600 (2670)

200 (890)

75.0 (111.8)

60940-48

6

48

8xCSM

.561 (14.2)

600 (2670)

200 (890)

97.0 (144.5)

60943-12

12

12

5xCSM

.463 (11.7)

600 (2670)

200 (890)

48.0 (71.5)

60943-24

12

24

5xCSM

.463 (11.7)

600 (2670)

200 (890)

52.0 (77.5)

60943-36

12

36

5xCSM

.463 (11.7)

600 (2670)

200 (890)

56.0 (83.4)

60943-48

12

48

5xCSM

.463 (11.7)

600 (2670)

200 (890)

60.0 (89.4)

60943-60

12

60

5xCSM

.463 (11.7)

600 (2670)

200 (890)

64.0 (95.4)

60943-72

12

72

6xCSM

.493 (12.5)

600 (2670)

200 (890)

76.0 (113.2)

60943-84

12

84

7xCSM

.552 (14.0)

600 (2670)

200 (890)

93.0 (138.6)

60943-96

12

96

8xCSM

.581 (14.8)

600 (2670)

200 (890)

106.0 (157.9)

60943-108

12

108

9xCSM

.620 (15.7)

600 (2670)

200 (890)

120.0 (178.8)

60943-120

12

120

10xCSM

.649 (16.5)

600 (2670)

200 (890)

137.0 (204.1)

60943-132

12

132

11xCSM

.683 (17.3)

600 (2670)

200 (890)

153.0 (228.0)

60943-144

12

144

12xCSM

.720 (18.3)

600 (2670)

200 (890)

171.0 (255.0)

60943-168

12

168

12x6xCSM

.737 (18.7)

600 (2670)

200 (890)

143.0 (213.1)

60943-192

12

192

12x6xCSM

.737 (18.7)

600 (2670)

200 (890)

151.0 (225.0)

60943-216

12

216

12x6xCSM

.737 (18.7)

600 (2670)

200 (890)

159.0 (236.9)

60943-240

12

240

13x7xCSM

.770 (19.6)

600 (2670)

200 (890)

175.0 (260.8)

60943-264

12

264

14x8xCSM

.805 (20.4)

600 (2670)

200 (890)

196.0 (292.0)

60943-288

12

288

15x9xCSM

.835 (21.2)

600 (2670)

200 (890)

213.0 (317.4)

60943-312

12

312

16x10xCSM

.870 (22.1)

600 (2670)

200 (890)

233.0 (347.2)

60943-336

12

336

17x11xCSM

.902 (22.9)

600 (2670)

200 (890)

255.0 (380.0)

60943-360

12

360

18x12x6xCSM

.956 (24.3)

600 (2670)

200 (890)

241.0 (359.1)

60943-384

12

384

18x12x6xCSM

.956 (24.3)

600 (2670)

200 (890)

249.0 (371.0)

60943-432

12

432

18x12x6xCSM

.956 (24.3)

600 (2670)

200 (890)

266.0 (396.3)

Loose Tube Outdoor Cable Applications

  • Suitable for Lashed Aerial, Duct, Underground Conduit Applications
  • Conventional Outside Plant Fiber Optic Cable for Video Security, Datacom, Broadcast, Telecom or Campus Backbone Applications
  • Outstanding Loss Consistency Across a Wide Range of Temperatures - Good for High Altitude Telescope Arrays, Underground Scientific Experiment Measurements Etc...

Loose Tube Outdoor Cable Optical Specifications

TIA/EIA-568-B.3/B.3-1
ISO/IEC 11801, 2nd Edition
Bellcore GR-20-CORE

 

50/125 µm Multimode
(OM2)

StratusClear 50/125 µm Multimode
(OM3)

Maximum Attenuation

≤3.25 dB/km @ 850 nm
≤1.0 dB/km @ 1300 nm

≤3.0 dB/km @ 850 nm
≤1.0 dB/km @ 1300 nm

Minimum Bandwidth (OFL)

500 MHz/km @ 850 nm
500 MHz/km @ 1300 nm

1500 MHz/km @ 850 nm
500 MHz/km @ 1300 nm

Minimum Bandwidth (RML)

510 MHz/km @ 850 nm
n/a

1400 MHz/km @ 850 nm
n/a

Gigabit Ethernet Support Distance

600 m @ 850 nm
600 m @ 1300 nm

1000 m @ 850 nm
1000 m @ 1300 nm

10 Gigabit Ethernet Support Distance

n/a
n/a

300 m @ 850 nm
n/a

Loose Tube Outdoor Cable Mechanical Specifications

  • Bend Radius, No Load = 10x Cable Overall Diameter
  • Bend Radius, Load = 20x Cable Overall Diameter

 

CABLING DISTRIBUTORS and CABLES WHOLESALE - Warehouse in Raleigh, North Carolina
Contact us Today for Quick Quotes, Consultations, Product Samples
Copper and Fiber Optic Cabling Specialists, Structured Cabling Systems, Newest Technologies and Products

| Home | Hitachi Indoor Outdoor Fiber | Hitachi Outside Plant Fiber | Armored Single Mode Fiber | Armored Multimode Fiber | Loose Tube 50 125 Multimode | Loose Tube 62.5 125 Multimode | Loose Tube Singlemode | Fiber Optic Cable | Hitachi Fiber Optic Cable | Voice Data Cable - Coaxial | DS3 and DS4 Cable

Products by Manufacturer
| HellermannTyton | Hitachi Cable Manchester | OCC Fiber | Coleman Cable | Winston International | AFL Telecommunications |
| Unicom | Sheer Wire | Lutron | On-Q Legrand | Crestron | Fluke Networks | Tripp Lite | Paladin Tools | Bogen |

| Quote Requests | Custom Cable Manufacturer | Send us your Files for Custom Cable assemblies | Home |

Copyright © 2017. All rights reserved

HDMI Switchers
Www.free-counter-plus.com <http://Www.free-counter-plus.com>
HDMI Switchers

 

This page requires the use of a frames-enabled browser.